Linear 7,100 electrical resisters are passive, non-electric, gas-driven devices designed to provide known constant resistance to the specified air current within the range of public and two-way movement. These resistors are designed to simulate the movement resistance of the patient's lung system and to help design, test, demonstrate and maintain the quality assurance of the respirator. The resistance series corresponds to anzi z79. 7-1976
(replaced by astm f1100-90), iso 80601-2-12, iso 80601-2-72 and iso 10651 series standards。
Hans rudolph 7100 r-gas stream linear resister, 7,100 r-gas current resister product characteristics:
• two-way linear
• resisting elements employ stainless steel and are durable
• each sequenced device provides calibration certificates
• provision of recalibration services (in and out)
• port adapter 22mm exterior cone, iso 5356-1:2015
• customizing electrical resisters to meet client requirements
• mri compatible customized resisters, as required
Hans rudolph 7100 r-gas stream linear resistor, 7100 r-gas current resistor specification material and dimensions
| Description |
Materials and dimensions |
| Port adapter (entry and exit) |
Pet thermal plastics, white – 22mm od cone |
| Resisting element (internal) |
Stainless steel |
| Gasket (internal) |
Pet thermal plastics, white |
| O circle (internal) |
Butler rubber, black |
| Diameter (assembly, maximum) |
1. 50” (3. 8 cm) |
| Length (assembly, typical) |
2. 92” (7. 4 cm) |
| Weight (assembly, typical) |
43 grams |
Applicable criteria
1. Iso 5356-1:2015 anaesthesia and respiratory equipment -- conical connectors
2. Iso 80601-2-12:2011 basic safety and basic performance of the intensive care respiratory apparatus
3. Iso 80601-2-72:2015 basic safety and basic performance of family medical breathing machines
4. Iso 10651 medical lung respirator
5. Astm f1100-90: 1997 respirators for intensive care
6. Ansi z79. 7-1976 medical respirator
Custom resisters
In consultation with hans rudolph inc., customized resisters can be provided according to customer specifications. Technical support because the flow range of each r value is limited
Designation (cmh2o/l/s, hpa/l/s)。
Custom resisters for the mri environment, made entirely from non-ferrous metal materials, may be requested。
Attention
1. Do not attempt to clean, disinfect or sterilize. This will render warranty and calibration ineffective。
2. Do not attempt dismantling. This will render warranty and calibration ineffective。
3. These resistors do not apply to respirators or other equipment
4. These resistors do not apply to any wet-gas flow circuits because the hydroccumulation in the resistance element affects calibration performance。
• these resistors do not apply to any type of respiratory circuit because there are no proven methods of cleaning, disinfection or sterilization, the result of which may cause biological harm to patients, clinicians and researchers。
• these resistors do not apply to any wetter patient or other air flow circuits, as the accumulation of moisture in the resistance element affects calibration performance。
• linear electrical resisters do not apply to the calibration standards for humans or as medical equipment。
Asi z79. 7-1976 and astm f1100-90:1997
| Model |
Marked as resistance value cmh2o/l/s |
Flow range (20% r accuracy) |
| 7100 r5 |
5 |
±2l/sec |
±120l/min |
| 7100 r20 |
20 |
±1l/sec |
±60l/min |
| 7100 r50 |
50 |
± 0. 5 l/sec |
±30l/min |
| 7100 r200 |
200 |
± 0. 1 l/sec |
±6l/min |
| 7100 r500 |
500 |
±0. 075l/sec |
±4. 5 l/min |
| 7100 r1,000 |
1000 |
± 0. 05 l/sec |
±3l/min |
Meet iso 80601-2-12: 2011, iso 80601-2-72:2015 and iso 10651 series standards
| Model |
Marked as resistance value cmh2o/l/s |
Flow range (20% r accuracy) |
| 7100 r5-cr1789 |
5 |
±1l/sec |
±60l/min |
| 7100 r10-cr1971 |
10 |
±0. 83l/sec |
±50l/min |
| 7100 r20-cr1790 |
20 |
±0. 83l/sec |
±50l/min |
| 7100 r50-cr1791 |
50 |
±0. 58l/sec |
±35l/min |
| 7100 r200-cr1792 |
200 |
± 0. 2 l/sec |
±12l/min |
| 7100 r400-cr1972 |
400 |
± 0. 1 l/sec |
±6l/min
|
Price Description
Price: The displayed price of Xiangpin on the Peanut Shell B2B Foreign Trade Information Platform may vary depending on Xiangpin's participation in activities, purchase quantity, or selected regulations. If the user reaches an agreement with Xiangjia offline, the settlement price of the offline agreement shall prevail. If the user completes an online purchase on the Peanut Shell B2B Foreign Trade Information Platform, the final settlement price on the order settlement page shall prevail.