Stimu-600 electro-stimulator detector, stimu-600 electro-stimulator function tester, is a measurement and test equipment for the performance of electrotherapy equipment for direct, low-frequency, medium-frequency or current-disruption work. Measurements and tests meet the conditions of iec 60601-2-10 (medical electrical equipment - components 2-10: special requirements for basic safety and basic performance of nerve and muscle irritant devices)。
Stimu-600 stimulator tester, stimu-600 stimulator functional tester system for iec 60601-2-10 stimulator functional test
- Touch screen or pc operation
- Graphical display of signals
- Measurement of effective current and effective voltage
- Measuring interfault current values
- Diagram recognition
- User-specific language settings
- Work power: +5 v usb or internal battery power
Protection level: internal battery power
Working temperature: +5 - +40 °c
Storage temperature: -10 - + 50 °c
Timer: off, 3, 5, 10 minutes, ± 1 second
Communications interface: 1 x mini usb
Test device connections: 6 4 mm plugins
Display: 4,3 inches of tft crystal
Measurement parameters: voltage current efficiency (maximum, effective, wave shape), display of input signals, frequency of input and performance signals, direct flow fractions, interference with currents, hit frequency。
The signal wave shape can be shown on the meter, and the results can be shown and stored by setting the test sequence
Provides three programmable and controllable measurement channels. Resist the range: 300 ohm, 500 ohm, 1,000 ohm, 2000 ohm and 10 kohm can also connect to 80 ohms external load。
3. Measurement of effective currents and effective voltage
The signal of the chosen channel can be measured and the value of the signal of each channel added to the sum。
4. Measurement of frequency: it is possible to measure both the frequency of the original signal and the frequency of the effective signal and the frequency of interference with it。
Straight-flow fraction: the direct-flow fraction obtained by low-transformation filter of 400 ms of the time constant。
6. Measurement of the current and frequency of interference: a signal with a fixed range fixed frequency for one channel and a signal with a fixed range change frequency for the other channel
Frequency bandwidth measurement accuracy to determine active value: 30 khz
Determines the validity of the input signal: ± 5 %
Maximum measured accuracy: ± 5 %
Straight-flow measurement accuracy: ± 5 %
Interference signal measurement accuracy: ± 5 %
Sine frequency determined: 0,5 hz - 10 khz ± 0, 1 hz or ± 5%
Stimu-600 electro-stimulator detector, stimu-600 utility tester technical parameters:
|
Interdiction |
Measurement range: ±0,1 v or 1 % |
||
|
|
± 10 v |
± 100 v |
± 700 v |
|
10000 ohm±3% |
0 – 1 ma |
0 – 10 ma |
0 – 70 ma |
|
2000 ohm ± 1 % |
0 – 5 ma |
0 – 50 ma |
0 – 350 ma |
|
1000 ohm ± 1 % |
0 – 10 ma |
0 – 100 ma |
0 – 700 ma |
|
500 ohm ± 1 % |
0 – 20 ma |
0 – 200 ma |
0 – 1400 ma |
|
300 ohm ± 2 % |
0 – 33 ma |
0 – 333 ma |
0 – 2333 ma |
|
80 ohm ± 2 % |
0 – 125 ma |
0 – 1250 ma |
0 – 875 ma |