Masimo radical-7 pulse oxidizer, radical-7 pulse co-oximeter characteristics and advantages:
More than 100 independent and objective studies have demonstrated that the most accurate and reliable spo2 readings can be provided at the time of movement and low injection。The upgraded masimo rainbow set technology platform allows you to add total haemoglobin and oxygen content to a simple on-site installation upgrade。
It is related to improving the level of care and reducing medical errors。
The use of the rainbow sensor enhanced detection。
Colour shows that key measurements can be immediately distinguished。
Clinical evidence of the world's highest sensitivity and speciality for pulse oxygen. Yi
Accurately for a violet patient
A signal iq waveform in the case of excess motion and low confidence noise, for signal recognition and quality indications
Unlike other pulsed blood ox, fastsat tracks rapid changes in oxygen in arterial blood at high levels of accuracy
High variable sound can provide a tune change of 1% for saturation
Satshare interface allows the transfer of spo2 and pulses to existing multi-parameter monitors and allows the reading of spco and spmet on adjacent radical-7 monitors
The screen automatically rotates to display monitors vertically, vertically or horizontally (not available for rds-2)
Remote alarm interface
Trends for 18 days
Portable handheld equipment that can be dismantled for patient transport
Desat index alarm allows clinicians to detect an increasing number of smaller saturations that may occur before respiratory conditions decline
Pi delta alarmtm warns of specific changes in clinical injections, which are usually reliable indicators of disease severity
Measurements of oxygen saturation (spoo2), pulse rate (pr) and injection index (pi) are standard; optional haemoglobins (spco®), high iron haemoglobins (spmet) and acoustic respiration rates (rra®) are available。


Masimo radical-7 pulse oxidizer, radical-7 pulse co-oximeter technical specifications
Measurement range
- Spo2:0 – 100%
- Spmet: 0 – 99. 9%
- Spco: 0 – 99%
- Sphb: 0 – 25 g / dl
- Spoc: 0 – 35ml o2/dl blood
- Pulse frequency: 25 – 240 bpm
- Injection index: 0. 02 – 20%
- Pvi: 0 – 100%
- Rra: 4 - 70 breaths per minute
- Oxygen saturation accuracy (%spo2)
- Saturation: 60 – 80 per cent
- Don't move
- Adult/baby/child: + 3%
- Don't move
- Saturation: 70 – 100%
- Don't move
- Adult/baby/child: + 2%
- Newborn: + 3%
- Don't move
- Sports
- Adult/baby/child/neonatal: + 3%
- Low injection
- Adult/baby/child/neonatal: + 2%
- Pulse frequency: 25 – 240 bpm
- Don't move
- Adult/baby/child/neonatal: +3 bpm
- Sports
- Adult/baby/child/neonatal: + 5 bpm
- Low injection
- Adult/baby/child/neonatal: +3 bpm
- Adult/baby/child: 1 – 40 + 3 %
- Adult/baby/child/newborn: 1 – 15 + 1 %
- Adults: 4 – 70 years, per minute + 1 breath
- Oxygen erythroglobin saturation (%spo02): 1%
- Carbonoxyglobin saturation (%spco), number: 1%
- Hemoglobin saturation (%spmet) in high iron, 0. 1%
- Pulse frequency (bpm): 1 bpm
- Respiration frequency (rra): 1 breath per minute
- Communication power requirements: 100 – 240 vac, 47 – 63 hz
- Consumption power: 55 va
- Wires: 1 amber, rapid response, public system (5x20mm), 250v
- Type: nickel hydrogen
- Capacity (battery lifetime): 4 hours
- Charge time: 3 hours
- Working temperature: 41°f to 104°f (5°c to 40°c)
- Storage temperature: -40°f to 158°f (-40°c to +70°c)
- Work humidity: 5 to 95 per cent, no condensation
- Working height: 500 mbar to 1060 mbar pressure; -1,000 to 18,000 ft (304 m to 5,486 m)
- Size: 8. 9 inches x 3. 5 inches x 2. 1 inches (22. 6 cm x 8. 9 cm x 5. 3 cm)
Trends
- At the 10-second spo2, sphb, spoc, spmet, spco, pulse, rra and injection index, at the 10-second resolution, the trend of 72 hours at a 2-second resolution, lasting more than 10 days, and exported to serial printers or other serial devices。
- Average pattern: 2, 4, 8, 10, 12, 14 or 16 seconds
- Sensitivity: normal, apod and maximum
- Rra average: 0, 10, 20, 30, 60 seconds
- Sound and visual alarms with high saturation and low pulse rates (1-99% spo2 range, 1-99. 5% spmet range, 1-24. 5 g/dl sphb range, 4-70 breathings per minute rra range, 0. 03-19% pi range, 1-99% pvi range and 30-235 bpm pulse rate)
- Data: %spoo2, %spmet, pulse rate, volume wave shape, rra wave shape, alert state, trends, status message, signal iq, injection index, max and apod sensitivity, pvi and fastsat
- Display colour: multicolour or monochrome blue
- Type: tft colour liquid crystal screen
- Pixels: 480 x 272 points
- Point spacing: 0. 20 mm
- 1 year warranty