Mini-x2 x-ray tubes, mini-x2 mini-x-ray tubes are a mini-x-ray tube system that includes x-ray tubes, power, control electronic equipment and usb communications with computers. It optimizes compact x-ray fluorescent (xrf) applications. Mini-x2 aims to simplify the xrf process by providing usb controls for the earth's anode, current and voltage, by installing simple accelerators on the 50kv model and by making it easier to operate。

| Maximum pressure | 50 kv | 70kv | |
| Maximum power | 4w | 10w | 10w |
| Anode | Ag, au, rh or w | Ag, au, rh or w | Gold, tungsten or tungsten |
Mini-x2 x-ray tubes, mini-x2 mini-x-ray system controllers include usb communications and software controls. It can be configured through software to support any x-ray tube module. 10 cable cable connection controller and x-ray tube module. The controller connection is 12 vdc power, usb for command and control, and aux connection with a secure locking device and a warning light drive。

Features
- 4 or 10 w output power
- 10 to 50 kv or 35 to 70 kv
- 5 to 200 μa (see e. G. Power curve)
- Ag, rh, au or w target (ag not available in 70kv)
- Usb control
Apply
- X-ray fluorescent (xrf)
- Portable and desktop instruments
- Online processing
- Teaching laboratories
Specifications
| 50 kv | 70kv | |
| Targets | Silver (ag), gold (au), tungsten (w) | (au), (rh), (w) |
| Target thickness | Ag and rh = 0. 75 μm (± 0. 1 μm) Au and w = 1. 00 μm (±0. 1 μm) |
|
| Tube voltage | 10 to 50 kv | 35 to 70 kv |
| Control the current | 5 μa minimum 200 μa maximum See figure 2 below |
5 μa minimum 200 μa maximum See figure 2 below |
| Approximate dose rate | Ag and rh: 1 sv/h (100 rem/hr)@axis 30 cm, 50 kv and 80 μa Au and w: 2. 2 sv/h (220 rem/hr)@axis 30 cm, 50 kv and 80 μa |
Data not available |
| Continuous output power | 100% max. 4 w or 10 w See figure 2 below |
100% of space ratio with maximum 10 w See figure 2 below |
| Window | Beryllium (be); windows on the ground | Beryllium (be); windows on the ground |
| Window thickness | 125 micrometres | 125 micrometres |
| Focus size | About 2 mm | |
| Cataract type | Tungsten (w) light | Tungsten (w) light |
| High pressure polarity | The earth's anode | The earth's anode |
| High voltage stability | < 0. 1% | < 0. 1% |
| Output flux stability | < 0. 3% (temperature stability) | < 0. 3% (temperature stability) |
| Output cone | 120° (see figure 3 and figure 4 below) | 120° (see figure 3 and figure 4 below) |
| Cool | It's cold | It's cold |
The radiation leak at 5 cm when the safety plug was installed |
<5 μsv/h (0. 5 mrem/h) | No security plug attachments |
| Energy consumption | 4w pipe: 9w @total power 10 w tube: 18 w @full power |
10 w electronic tubes: 18 w @full power |
| Input voltage | 12 vdc (including communication adapters) | 12 vdc (including communication adapters) |
| Control | Usb, mini usb connectors (including cables) | Usb, mini usb connectors (including cables) |
| Stabilization time | Typical < 1 sec | Typical < 1 sec |
| Weight | ~400 grams | < 700 g |
| Humidity | 30% to 90%, not condensed | 30% to 90%, not condensed |
| Working temperature range | -10 °c to +50 °c | -10 °c to +50 °c |
| Storage temperature range | -25 °c to +60 °c | -25 °c to +60 °c |
| Security controls and indicators | 1) interlocking external hardware 2) led flash 3) beeps |
1) interlocking external hardware 2) led flash 3) beeps |
| Software | Mini-x2 control software to control voltage and currents。 Mini-x2 api for custom programming applications。 |
Mini-x2 control software to control voltage and currents。 Mini-x2 api for custom programming applications。 |
| Insurance policy | One year or 2000 hours, whichever is first arrived | One year or 2000 hours, whichever is first arrived |
Figure 2. Power such as mini-x2. The current and voltage must be set according to this curve, otherwise mini-x2 may be seriously damaged. Such damage is not covered by the warranty. The amptek control software limits the power of this curve. If the power of the command system exceeds the power limit, the software will use the command hv and roll back to meet the power limit. Note that the curve varies by tube。
Figure 3. Mini-x2 angle response, 120° cone。
Note: x-ray cone angles can be reduced when a straighter is used, see the approximate reference below。
| Accurate diameter | X-ray conical angle |
| 1 mm | 3° |
| 2mm | 5° |
| 3mm | 8° |