Hansrudolph calibrates the product characteristics of syringe 5520/5510/5550/5540/5530/5570/4900
• the calibration of syringes ranged from 10 ml to 7,000 ml in the volume of the whole alluvial。
• precision tank routing is either a fine grinding of aluminides or mechanical processing and polishing of acrylic acid
• sealed elements are either specially designed for high wear and lubricant rubber or machine-processed flat springs
Loading pure teflon kit
• pistol poles are aluminum grinding and black anodes or plastic glass filling nylons
Pistol scale is either bed cutting (processing) or laser tag
• provides a standard and custom-sized export end mouth
• sliding is stopping the collar as a different delivery volume, including tightening the trigger hands
• in-situ availability of plugs to detect syringe leaks
• certification of the volume of each syringe and leakage tests
Three litres of syringes are used to calibrate pulmonary function test equipment, including: koko pulmonary activity meter, cyber medic full gas systems, morgan scientific and collins full gas systems。The standard calibration syringes with known calibration volumes provide a simple and reliable method of regularly and reliably calibrating and measuring the accuracy of the on-site respiratory measurement equipment to meet quality assurance procedures. It is recommended that three litres be used as the minimum volume for testing lung activity。
Hansrudolph calibration syringe 5520/5510/5550/5540/5530/5570/4900
Volume calibration syringes are measurement equipment designed to test and calibrate traffic and volume for use in the market for respiratory equipment. The calibration syringe is manual and the export port of the syringe component that drives the piston into and out of the cylinder should be installed on the detector. Hans rudolph
Customized export ports are provided to match the calibration syringes of any pulmonary activity measurement devices in the market to transport known volume air to flow or volume measuring equipment on start-up. The operator compares the volume of the calibrated syringe delivered with the volume of the syringe delivered with the volume obtained from the measured equipment to determine the accuracy。
Calibration of syringes for respiratory flow meters
Pulmonary measures. These devices are typical components of the pulmonary activity measurement system
As well as pulmonary function testing system calibration syringes for lung function testing laboratories, biomedical engineering calibration laboratories, private physician offices, universities, research centres and respiratory system manufacturers。
Hansrudolph calibrated syringes 5520/5510/5550/5540/5530/5570/4900
|
Model/parameter |
5520 |
5510 |
5550 |
5540 |
5530 |
5570 |
4900 |
|
|
Precision |
Ml |
± 0. 05 |
±0. 5 |
±2. 5 |
±5. 0 |
±15. 0 |
±15. 0 |
±35. 0 |
|
Total volume |
Ml |
10 |
100 |
500 |
1000 |
3000 |
3000 |
7000 |
|
Minimum volume |
Ml |
Two |
20 |
50 |
50 |
100 |
3000 |
100 |
|
Scramble volume |
In |
Three |
5 |
6. 25 |
12. 38 |
14. 75 |
14. 75 |
15 |
|
And |
7. 6 |
12. 7 |
15. 8 |
31. 5 |
37. 5 |
37. 5 |
38. 1 |
|
|
Air tank inner diameter |
In |
0. 50 |
1. 25 |
2. 50 |
2. 50 |
4. 0 |
4. 0 |
6. 0 |
|
And |
1. 27 |
3. 17 |
6. 35 |
6. 35 |
10. 16 |
10. 16 |
15. 24 |
|
|
Weight |
Lb |
17 |
39 |
1. 7 |
Two |
3. 7 |
3. 6 |
10 |
|
Gm |
75 |
175 |
771 |
907 |
1690 |
1655 |
4536 |
|



VIP会员