The accusim monitor simulator, the accusim monitor detector, will be accurately simulated, tested and calibrated for all patients and approved by masimo, welch-allyn and other major manufacturers。
Our approach was developed in cooperation with the world's leading patient watch manufacturer, accusim being the only simulator with such extensive guardianship functions。
A fully synchronized patient watch simulation system
Internal pressure meters and high-precision pressure sensors
Use caltables for accurate nibp simulations
The inner adult has no blood pressure sleeves
Accurate second generation spo2 simulation with r curve
Accurate testing of rainbow technology in masimo and other new pulsed blood saturation measurement techniques
12 coronary electrogram simulation
There's a blood pressure simulation
Respiration simulation
Temperature simulation
Heart disorder and pacemaker
Usb connection
The internet can update solidware
Preset the spo2 r curve to make surveillance easier
- Bci
- Triticare
- Csi-spot
- Datascope
- Data
- Hewlett-packard (philips)
- Masimo
- Nellcor
- Nellcor oxford
- Nihan kohden
- Nonin
- Novametrix
- Ohmeda
- Sensormedics
Measurement range: 10~295 mmhg;
Measurement precision: ±0. 5 mmhg
Use: combining multiple-parametric simulations of blood pressure, blood oxygen saturation, electrocardiology, etc. In a single detection device
Accusim multi parameter monitor integrated tester product characteristics
A combination of multiple-parametric simulations of blood pressure, blood oxygen saturation and electrocardiologyA combination of haematological saturation and electrical simulations
An unceremonious blood pressure algorithm simulation (caltablestm) authorized by the manufacturers of over a dozen mainstream custodians such as ge, philips, spacelabs, etc
High-precision blood oxygen r curves certified by manufacturers (including philips, omeda, masimo, nellcor, etc.)
Blood pressure simulation accuracy: ± 0. 5 mmhg
Technical parameters
No blood pressure
(b) pre-set blood pressure simulation values for 7 constituents and 6 groups of newborns
Blood pressure simulation range: 10~295 mmhg
Pulse range: 15~330 bpm
Pulse amplitude: 0-150%
Static pressure range: 0. 0~400. 0mmhg
Precision: ± 0. 5 mmhg
Internal gas pumps to support pressure leaks, pressure protection tests and digital pressureometer functions
Blood oxygen saturation
Pre-set 14 groups of blood oxygen r curves
Scope: 0~100spo2%;
Accuracy: ± 0. 5 spo2 per cent (70 ~ 100 spo2 per cent), ± 1 spo2 per cent (50 ~ 69 spo2 per cent)
Infusion range: 0. 10-20. 0%
May be subject to interference with environmental light, work frequency/multi-frequency, motion, heart disorder, etc.
Cardiac
Heart rate: 30 ~ 330 bpm
(b) carnet: 0. 15-5. 00 mv
Supporting adjustment of parameters such as pace, s-t segment, t-wave, r-r period
(b) cardiopathic disorders: hypercardial hyperactivity, hypercardial hyperactivity, room tremors, room tremors, stoppages, etc.
Breathe
Respiratory rate: 4~120 brpm
Baseline resistance: 250, 500, 750, 1,000
Temperature
Scope: 0. 0~50. 0°c
It's blood pressure
Static pressure: 0~300 mmhg (step 1 mmhg)
Outer size
4. 25 inches wide x 2 inches high x 11. 5 inches long
Including built-in adult sleeve support