All sensor elements are protected by elastic resins for heat protection。
M60-3 pvdf pressure sensor
M60-3 pvdf pressure sensor application• gas experiments
• ideally installed in a tremors tube (for end walls, m100-1)
• with kiag connector
• excluding individual cables, clauses 800-200-1
• the same size as quest 603b
• packages for walls, articles - none. 100-290-1
• need charge amplifier müller mcpa 10 or quartz happy
M60-3 pvdf pressure sensor technical parameters:
Uptime: 60 ns
Sensory diameter: 3 mm
Outer diameter: 5. 5 mm
Sensitivity: 4 pc/bar
Cable: kiag m4x0. 35 sep. 2 m cable
M60-3l pvdf pressure sensor
M60-3l pvdf pressure sensor application
• same sensors as m60-3, but also for liquids and ultrasounds
• explosive waves in liquids
• use of direct waterproof cables
• same head as m60-3
• in the case of short pulses, direct connection to a recorder recommendation with 1 mohm input
• a charge amplifier mcpa 10 is required if there is a longer pressure wave or longer cable extension
Technical parameters for m60-3l pvdf pressure sensor:
Uptime: 60 ns
Sensory diameter: 3 mm
Outer diameter: 5. 5 mm
Sensitivity: 4 pc/bar
Cables: with taxes 2 m cable, waterproof
M60-1l pvdf pressure sensor
M60-1l pvdf pressure sensor application
• experiments in gases
• the ideal option for an explosion chamber, which could lead to an impact wave
• thermal protection lasts from 80 to 100 ms
• recommended use of charge amplifier mcpa 10
• walled, articles 100-290-3
• excluding cables, articles 800-200-1
M60-1l pvdf pressure sensor technical parameters:
Uptime: 40 ns
Sensory diameter: 1 mm
Outer diameter: 2. 5 mm
Sensitivity: 0. 4 pc/bar
Cables: with taxes 2 m cable
M60-1l-m3 pvdf pressure sensor
M60-1l-m3 pvdf pressure sensor application
• experimentation in gases or liquids
• use of direct waterproof cables
• with an m3 screw, which can easily be installed directly in the walls
• the rubber o circle provides close connectivity
• application similar to m60-3l
Technical parameters for m60-1l-m3 pvdf pressure sensor:
Uptime: 40 ns
Sensory diameter: 1 mm
Exterior: m3
Sensitivity: 0. 4 pc/bar
Cables: with taxes 2 m cable
M60 pvdf pressure sensor, muller m60 pressure sensor generic technical parameters:
| Scope: | -20 to 400 bar (-2 to 40 mpa) |
| Rise time: | 40-100 ns |
| Bandwidth: | Up to 15 mhz) |
| Sensitivity: | M60-3: about 5. 0 pc/bar |
| Bandwidth: | Up to 15 mhz) |
| Sensitivity: | M60-3: approximately 5. 0 pc / bar and m60-1l: approximately 0. 4 pc / bar |
| Calibration: | Steady-state shock tube calibration as high as 10 bar。 |
| Sensitivity diameter: | M60-3: 3. 0 mm |
| Calibration: | Steady-state shock tube calibration as high as 10 bar。 |
| Sensitivity diameter: | M60-3: 3. 0 mm & m60-1 / m100-1: 1. 0 mm |
| Polar: | Negative |
| Capacity: | About 30 pf |
| Stop: | > 101° om |
| Sensitive elements: | Voltage pvdf |
| Temperature range: | - 20 to + 65 degrees c, slightly higher |
| Housing: | Stainless steel, sensitive elements covered with elastic resin |
| Dimensions: | |
| M60-3 / m100-1: | 6. 3 mm x 12 mm |
| M60-3l: | 6. 3 x 28 mm |
| M60-1l-m3: | M3 x 27 mm |
| M60-3: | 1. 4 grams |
| Organisation | |
| M60-3 / m100-1: | Kiag m4 x 0. 35, cable article #800-200-1 |
| M60-3l, m60-1l type: | With 2m waterproof cable and bnc pos。 |