The netech lkg 610 electrical safety analyser, the lkg 610 safety tester, is a hand-held electrical security analyser based on microprocessors for testing any medical equipment。
The full-function tester has 10 lead lines for snapshots and any postings. When the corresponding key is pressed, the test can be performed quickly and easily. The survey results show that the measurement units are clearly shown by leds on large ccds. Large switches change polarity, open and close gaps and lift the ground。
In addition to standard electrical safety tests, lkg 610 can also perform iso and point-to-point measurements. The calibration test points ensure accuracy and repetitivity. You can choose the aami or iec601 test load. The fuse is accessible。
Lkg 610 provides the optimal combination of functionality, performance and value of any portable electrical safety analyser。
Netech lkg 610 electrical safety analyser, lkg 610 security tester characteristics:
Quick, accurate, portable
Accessibility
Large lcd monitor
Accessible circuit fuses
The calibration test point
Optional test load
15 and 20 amphibians
Point-to-point test
Use any test cables
General connection to 10 lead lines
Matching aami and iec 601-1 test load
Led measurement unit indicator
Netech lkg 610 electrical safety analyser, lkg 610 ambient test measure:
*input polarity
*line voltage
*cable cable resistance
*the shell leaks the current
*the leak of electricity
:: cause leakage
*guidance iso testing
* instrument current
* point-to-point measurements
Netech lkg 610 electrical safety analyser, lkg 610 safety tester specifications:
Show:
Lcd 3 1/2 bit
Work voltage:
110 vac or 220 vac (optional)
Measurement range:
Interception: 0-1999 mw
Leakage: 0-1999 ma
Instrument current: 0-19. 99 an peasant
Precision:
Interception: +/- 2% + / - 1 lsd
Leak:
+/- 1% fs dc to 1 khz +/-1 lsd
+/- 2% fs dc 1 khz to 100 khz
+/- 4% fs 100 khz to 1 mhz
Instrument current: +/- 2% +/- 1 lsd
Dimensions:
8 x 4. 5 x 2 inches (20. 3 x 11. 4 x 5 cm)
| Show: 3 1/2-bit lcd display |
| Measurement range |
| Electrical resistance:0 - 1999 mille leak current: 0 - 1999 microamp instrument current: 0 - 19. 99 ann. Peasant |
| Precision |
| Electrical resistance+/- 2%+/- 1 lsd leak: +/- 1% to 1 khz +/- 1 lsd +/- 2% fs 1 khz to 100 khz +/- 4% fs 100 khz to 1 mhz instrument current: +/- 2% +/- 1 lsd |
| Power requirements |
| 110 vac 50 - 60 hz, 20 amp or 220 vac 10 amp is used for test outlets and 0. 1 amps is used for equipment。 |
| Temperature |
| Working temperature range: 59-95 fahrenheit (15-35 c) storage temperature: 0 to 122 degrees fahrenheit (-18 to 50 degrees celsius) |
| Relative humidity |
| 90% temperature (maximum) |
| The calibration test point |
| References:1 om leak: 200 μa |
Netech lkg 610 electrical safety analyser, lkg 610 safety tester weight:
2. 5 pounds (1. 1 kg)