Key Point:As technology evolves, the type of household electricity becomes more abundant and, as far as air conditioning is concerned, the array, wall, frequency, intelligence, etc. Are fully functional。However, after a long period of use, air conditioners have suffered minor malfunctions, and today they share common failures and maintenance methods。Methodology/step1. Compressor inoperableReason for failure: power failureMethod of exclusion:

As technology evolves, the type of household electricity becomes more abundant and, as far as air conditioning is concerned, the array, wall, frequency, intelligence, etc. Are fully functional。

However, after a long period of use, air conditioners have suffered minor malfunctions, and today they share common failures and maintenance methods。

Download of technical information on air conditioning maintenance

Methodology/step

1. Compressor inoperable

Reason for failure: power failure

Method of exclusion: dismantling of malfunctions by universal-use watch and electronic pen. The fuse is broken, the fuse is replaced, and the wire is broken。

Reason for failure: power pressure is too low

Method of exclusion: measurement of voltage values on a single scale and, if necessary, power-pressure devices。

Causes of failure 3: loose or broken wire connections

Method of exclusion: inspection of wire connections, re-insulation of loose plugs, tightening of plugs, professional overhaul。

Download of technical information on air conditioning maintenance

Wind machines are not operational

Reason for failure: poor contact with the main switch

Method of exclusion: the main switch contact point electrical resistance is measured on a universal scale and should be repaired or replaced when the resistance is too large or zero。

Fault cause 2: fan wire damage

Method of exclusion: replacement of fans with the same specifications and the same speed with a universal watch。

Causes of failure 3: loose bolts between wind engine electrics and wind leaves

Method of exclusion: tightened screws。

Causes of failure 4: break-down or short of fan capacitors road

Method of exclusion: inspection of capacitors and replacement of capacitors of the same specifications。

Download of technical information on air conditioning maintenance

3. Compressor start and stop frequency

Reason for failure: inappropriate room temperature control

Method of exclusion: increase, as appropriate, the margin between indoor control temperature and primary temperature。

Reason for failure: over-temperature

Method of exclusion: improvement of the working environment, such as the installation of a fence, avoidance of sunlight, installation of air conditioners in a well-ventilated environment, etc。

Reason for failure 3: condensers are dirty

Method of exclusion: clean the condenser and remove the dust from the outer surface of the condenser。

Download of technical information on air conditioning maintenance

4. Non-regulated heat-refrigeration function of hac

Reason for failure: electromagnetic switch to valve loop failure

Method of exclusion: the electro-magnetic membrane measure is used to convert to the valve wire, and if it is broken or burned, a new electro-magnetic valve of the same size should be replaced。

Reason for failure: failure of electrical heating unit

Method of exclusion: replacement of electro-heated silk or temperature protections of the same specifications with a universal watch check。

Causes of malfunction 3: temperature controller failure

Method of exclusion: the temperature controller of the same specification shall be replaced with a universal meter to check the thermostat, and if it is still ineffective after de-stereolysis of the contact point。

5. Leakage

Reason for failure: the horizontal tilt angle of window air conditioner installation is insufficient

Exclusion method: window air conditioners are re-installed in the correct manner。

Reason for failure: drain blockage

Method of exclusion: clean-up of congestion。

Reason for malfunction 3: inadequate level of interior installation

Method of exclusion: re-equipment of indoor aircraft using a horizontal device。